Go back to search results

Smart Thermostats

Manufacturer
Venstar Inc.
Brand Name
Venstar
Model Number
T4###
Qualifying Entity
ENERGY STAR®
Additional Model Info
T4800, T4900
Notes
Date Available on Market
5/9/2015
Date Qualified
10/31/2018
Purchase By Date (Date Delisted)
Model Name
Explorer
Kit Model Number 1

Extended Properties

Use CTRL-F to search for a property or value.

Energy Star Partner
Venstar Inc.
Brand Name
Venstar
Model Name
Explorer
Model Number
T4###
Additional Model Information
,,Family Model Differences: Commerical vs Residental; Humdity control vs no humidity Control; differences in number of buttons, number of control outputs, and minor differences in features.; Explorer,T4800,; Explorer,T4900,
Date Available on Market
5/9/2015
Date Qualified
10/31/2018
Markets
United States, Canada
Energy Star Model Identifier
ES_1048765_T4###_03192020141819_7499475
Pd Id
2356695
Upc
Ct Device Brand Owner
Venstar
Ct Device Brand Name
Venstar
Ct Device Model Name
Explorer
Ct Device Model Number
T4###
Additional Ct Device Model Numbers
T4800, T4900
Family Id
FAM_1048765_02042019195535_0136140
Static Temperature Accuracy
1.38
Network Standby Average Power Consumption
0.62
Time to Enter Network Standby After User Interaction
0
Ct Product Heating and Cooling Control Features
Time of Day Usage
Other Heating and Cooling Control Features
Ct Device Communication Method
Wi-Fi
Communication Method Other
Demand Response Summary
Venstar through our Skyport Cloud Services provides OpenADR compliance for all of the Venstar communicating thermostats with WiFi. These OpenADR compliant products provide solutions for both the Residential and Commercial markets. Skyport Cloud Services OpenADR VEN is a certified DR solution that allows utilities or verified energy partners to push DR signals that include load shedding, price notifications, and price actions to Skyport Cloud connected Venstar thermostats. Skyport Cloud Services allow the utilities or verified energy partners to group thermostats into logical groups and regions to send directed DR events. Skyport Cloud users have the ability to adjust the Maximum Cooling Setpoint, Minimum Heating Setpoints, Offset Settings and Price Trigger settings for DR events. Once a DR event is completed, Skyport Cloud Services, with detailed reporting capability, generates a report signal back to the load management entity for the success rate of the DR event. Venstar communicating thermostats are Title 24 compliant.
Demand Response Product Variations

{
  "energy_star_partner": "Venstar Inc.",
  "brand_name": "Venstar",
  "model_name": "Explorer",
  "model_number": "T4###",
  "additional_model_information": ",,Family Model Differences: Commerical vs Residental; Humdity control vs no humidity Control; differences in number of buttons, number of control outputs, and minor differences in features.; Explorer,T4800,; Explorer,T4900,",
  "date_available_on_market": "2015-05-09T00:00:00",
  "date_qualified": "2018-10-31T00:00:00",
  "markets": "United States, Canada",
  "energy_star_model_identifier": "ES_1048765_T4###_03192020141819_7499475",
  "pd_id": "2356695",
  "upc": "",
  "ct_device_brand_owner": "Venstar",
  "ct_device_brand_name": "Venstar",
  "ct_device_model_name": "Explorer",
  "ct_device_model_number": "T4###",
  "additional_ct_device_model_numbers": "T4800, T4900",
  "family_id": "FAM_1048765_02042019195535_0136140",
  "static_temperature_accuracy": "1.38",
  "network_standby_average_power_consumption": "0.62",
  "time_to_enter_network_standby_after_user_interaction": "0",
  "ct_product_heating_and_cooling_control_features": "Time of Day Usage",
  "other_heating_and_cooling_control_features": "",
  "ct_device_communication_method": "Wi-Fi",
  "communication_method_other": "",
  "demand_response_summary": "Venstar through our Skyport Cloud Services provides OpenADR compliance for all of the Venstar communicating thermostats with WiFi. These OpenADR compliant products provide solutions for both the Residential and Commercial markets.\nSkyport Cloud Services OpenADR VEN is a certified DR solution that allows utilities or verified energy partners to push DR signals that include load shedding, price notifications, and price actions to Skyport Cloud connected Venstar thermostats. Skyport Cloud Services allow the utilities or verified energy partners to group thermostats into logical groups and regions to send directed DR events. Skyport Cloud users have the ability to adjust the Maximum Cooling Setpoint, Minimum Heating Setpoints, Offset Settings and Price Trigger settings for DR events. Once a DR event is completed, Skyport Cloud Services, with detailed reporting capability, generates a report signal back to the load management entity for the success rate of the DR event.\nVenstar communicating thermostats are Title 24 compliant.",
  "demand_response_product_variations": ""
}

Manufacturer / Brand
VENSTAR INC. VENSTAR
Model Number
T4
Model Number 2
Additional Model Numbers
EXPLORERT4800T4900
Wildcard Model Number(s)
T4***